Ranger Valve America

Technical Guide

API 6D vs API 600: what is the difference?

The short answer

API 6D covers pipeline valves: ball, gate, plug and check valves for pipeline transportation systems, with requirements for pig passage, cavity relief, block-and-bleed and buried service. API 600 covers one product, bolted-bonnet steel gate valves for refinery, petrochemical and general process piping. Choose by service and by your piping specification. The two are not interchangeable.

Ranger Valve America Ltd. · Last reviewed

What each standard covers

API 6DAPI 600
TitleSpecification for Pipeline and Piping ValvesSteel Gate Valves: Flanged and Butt-welding Ends, Bolted Bonnets
Valve typesBall, gate, plug and check valvesGate valves only
Typical servicePipeline transportation, pump and compressor stations, terminalsRefineries, petrochemical plants and general process piping
ISO counterpartISO 14313ISO 10434
PiggingIncludes full-bore, through-conduit designs for piggable linesWedge gate designs, not intended for pigging
Features it addressesCavity relief, double block and bleed, sealant injection, anti-static and fire-safe design, buried serviceBody, bonnet, stem, wedge and trim design and materials for bolted-bonnet gate valves
Inspection and testingIts own shell and seat test requirementsReferences API 598

When each one applies

API 6D is the pipeline valve standard. It applies when the valve is part of a pipeline system and may have to pass pigs, be buried, provide double block and bleed isolation, or be repaired in line. API 6D gate valves are through-conduit designs, slab or expanding gate, with a full-bore flow path.

API 600 is the standard for general-purpose steel wedge gate valves in plant piping: refineries, chemical and petrochemical facilities, and power and process systems. It is a design standard for the gate valve itself and relies on API 598 for inspection and testing.

Can one replace the other?

Not by default. The two standards set different design, testing and documentation requirements, and your piping class or project specification states which one applies to each valve. An API 6D gate valve is sometimes specified in plant piping where a full-bore flow path or double block and bleed is needed, but that is a specification decision, not a substitution. If you are unsure, include the line list or valve data sheet with your quote request so the standard can be confirmed before pricing.

RANGER valves by standard

StandardRANGER productSizeClass
API 6DTrunnion ball valves2" – 56"150 – 2500
API 6DFloating ball valves1/2" – 10"150 – 600 (cast); 600 – 1500 (forged)
API 6DThrough conduit slab gate valves2" – 48"150 – 2500
API 6DExpanding gate valves2" – 48"150 – 2500
API 600Cast steel gate valves2" – 60"150 – 2500

RANGER-FZV holds API Monogram licenses for API 6D (since 2000) and API 600 (since 2006), under a quality management system certified to API Q1. See API 6D ball valves, API 6D gate valves and cast steel valves, or read about quality control.

Frequently asked questions

Is API 6D the same as ISO 14313?

They cover the same subject, valves for pipeline transportation systems, and are closely aligned. API 6D is the API document and ISO 14313 is the ISO one, so check which your specification names.

Does API 600 cover ball valves?

No. API 600 covers steel gate valves only. Ball valves are covered by API 6D for pipeline service and API 608 for general-purpose service.

Which standard covers check valves?

API 6D covers pipeline check valves. API 594 covers wafer, lug and flanged check valves for plant piping, including dual-plate designs.

Why would a pipeline project specify API 6D instead of API 600?

API 6D adds requirements that pipelines need and a general-service gate valve standard does not address, such as pig passage, cavity relief, block-and-bleed capability and buried service.