The short answer
API 624 is the type test for rising stem valves, such as gate and globe valves, fitted with graphite packing. A valve design is cycled with methane while stem leakage is measured: 310 mechanical cycles and 3 thermal cycles. A valve that passes is qualified as low-emission within the size, class and temperature range stated in the test report. It is a design qualification, not a test of every valve produced.
Ranger Valve America Ltd. · Last reviewed
What API 624 covers
API 624, Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions, tests a valve design for leakage through the stem seal. Fugitive emissions are the small leaks of volatile air pollutants and hazardous fluids from stem packing and body joints that, added up across a plant, matter for both regulation and safety.
The standard is a type test. It qualifies a design, within the ranges the report states, rather than testing each valve as it is built. It applies to rising stem valves with graphite packing. Quarter-turn valves, such as ball and butterfly valves, are covered by a separate standard, API 641.
How the test works
These are the parameters of the API 624 test conducted by Chesterton, the graphite packing manufacturer and an authorized API 624 test facility, on RANGER cast steel gate and globe valves:
| Parameter | RANGER test |
|---|---|
| Test medium | Dry methane gas, 97% minimum purity |
| Test pressure | 600 psi / 4.13 MPa |
| Test temperature | Ambient and 260 °C / 500 °F |
| Thermal cycles | 3 |
| Mechanical cycles | 310 |
| Emissions measurement | Static and dynamic conditions, taken at the stem and the packing outside diameter every 50 cycles |
| Method | Based on elements of EPA Method 21 |
| Valves qualified | All sizes up to and including 24 in / 600 mm, all classes up to and including 1500 |
| Operating temperature range | -29 °C to 538 °C / -20 °F to 1000 °F |
How to specify it
- Ask for the API 624 test report for the valve design you are buying, not just a statement that the valve complies.
- Check that the report covers your size, class and operating temperature, and that the packing, stem finish and stuffing box are the same as the valve that was tested.
- Specify production testing separately if you need it, for example ISO 15848-2 or Shell MESC 77/312, because API 624 itself is a type test.
- State the stem packing arrangement. Live loading, with spring washers under the gland nuts, keeps a constant load on the packing, and RANGER quotes 5,000 or more cycles before adjustment or repacking.
- For ball and butterfly valves, ask for the quarter-turn equivalent, API 641 or ISO 15848-1, not API 624.
API 624 valves from RANGER
RANGER cast steel API 600 gate valves (2" – 60", Class 150 – 2500) and API 623 globe valves (2" – 60", Class 150 – 2500) are qualified to API 624 up to 24 in and Class 1500, using Chesterton graphite packing. The standard also appears on RANGER's API 6D slab and expanding gate valves. Where a fugitive emission standard is specified, RANGER tests samples of standard production valves at the factory, and can also supply testing to ISO 15848-2 and Shell MESC 77/312 on request.
See API 600 gate valves, API 623 globe valves, slab gate valves and expanding gate valves.
Frequently asked questions
Is API 624 testing mandatory?
Only when your specification, the operator or the applicable regulation calls for it. It is commonly requested for valves in volatile-organic or hazardous service.
What is the difference between API 622 and API 624?
API 622 tests the graphite packing on its own. API 624 tests a complete rising stem valve fitted with that packing. A valve with API 622 packing is not automatically API 624 qualified.
Does API 624 apply to ball valves?
No. API 624 is for rising stem valves with graphite packing. Quarter-turn valves, including ball and butterfly valves, are covered by API 641 or tested to ISO 15848-1.
Is every valve tested to API 624?
No. API 624 is a type test: a design is qualified once, within the size, class and temperature range in the test report. Production testing, for example to ISO 15848-2, is a separate requirement.
Which RANGER valves are qualified to API 624?
RANGER cast steel gate and globe valves up to 24 in and Class 1500. The test was conducted by Chesterton. API 624 also appears in the standards for RANGER's API 6D slab and expanding gate valves.
Request the brochure
The cast steel gate, globe and check valve catalogue has a fugitive emissions section with the API 624 test parameters, the qualified range and the additional tests RANGER can supply.
Select what you'd like below and we'll email you secure download links.