What is an axial flow check valve?

The short answer

An axial flow check valve, also called a nozzle check valve, has a streamlined body with a disc that moves along the flow axis and is closed by a spring. The spring starts closing the disc as the flow slows, and the disc has only a short distance to travel, so the valve is already closed when the flow tries to reverse. That reduces the slam and water hammer a swing check valve can cause, which is why axial flow check valves are used on pump and compressor discharge lines and other critical equipment.

Ranger Valve America Ltd. · Last reviewed

How an axial flow check valve works

The body is shaped like a nozzle: the flow passage narrows and then widens again around a disc, or plug, that is guided on a central stem along the pipe axis. Forward flow pushes the disc off its seat against a spring. When the flow slows, the spring pushes the disc back toward the seat, and when the flow stops or tries to reverse, the disc closes.

Three things distinguish the design. The flow path is streamlined: the passage narrows around the disc and then widens again, so the flow stays smooth, pressure loss is low, and the faster flow through the narrow section helps hold the disc open at normal flow. The disc travels only a short distance between open and closed, and it is usually the only moving part, so there is little to wear. And the spring and the low mass of the disc let it respond quickly: the choice of spring sets how fast the valve closes, so the spring is selected for the duty.

Why it reduces slam and water hammer

In a swing check valve the disc hangs on a hinge and swings through a large arc. It is closed by gravity and by the reverse flow itself, so it does not seat until some reverse flow has already developed. When it finally slams shut, the moving column of liquid stops suddenly and a pressure surge, water hammer, travels through the piping. The surge can damage the pump, the pipe supports and the valve. The risk is highest when the fluid moves fast, when a long column of liquid is moving, and when the piping has large elevation changes.

An axial flow check valve closes earlier, while the flow is still decelerating, and has less distance to travel. With less reverse flow before the valve closes, the surge is much smaller. This is the reason RANGER describes its axial-flow nozzle design as the preferred solution for preventing backflow or water hammer on critical process equipment.

Axial flow, swing and dual plate check valves compared

Axial flow (nozzle) checkSwing checkDual plate wafer check
Closing mechanismSpring-loaded disc on a central axisHinged disc, closed by gravity and reverse flowTwo spring-assisted plates on a central hinge pin
Travel of the discShort strokeLarge arcShort, each plate moves a small angle
Slam and water hammerGreatly reducedCan be severe on fast flow reversalReduced by the spring assistance
Flow pathStreamlined, with the disc in the flowStraight through when open on a full-port valvePlates remain in the flow; compact face to face
PiggingNot suited to piggingRANGER API 6D swing check valves are full-port and piggableNot suited to pigging
Typical usePump and compressor discharge, critical process equipmentPipelines and general service with a long, clean runCompact installations between flanges
RANGER size2" – 40"2" – 60"See the dual door wafer page
RANGER class150 – 2500150 – 2500See the dual door wafer page

Where to use an axial flow check valve

  • Pump discharge lines, where a fast, quiet closure protects the pump from reverse flow and the piping from surge.
  • Compressor suction, discharge and bypass, boiler feedwater, cooling water and other critical process equipment, where a slamming check valve is unacceptable.
  • Reciprocating compressors and other pulsating flow, where the flow keeps starting and stopping and a conventional swing check disc tends to flutter and chatter.
  • Services with clean liquids or gases. The valve has a guided disc and a spring in the flow path, so heavy solids or slurries can foul it.
  • Lines that are not pigged. The disc and its guide stay in the flow, so use a full-port swing check valve where pigging is needed.

What to specify

What the supplier needs on the data sheet

Line size and pressure class; end connections; the fluid, whether it is a liquid, gas or steam, and its specific gravity; design pressure and temperature; the minimum, normal and maximum flow, pressure and temperature; the installation orientation and flow direction; the service; body, trim, spring and seat materials; and any sour service, inspection or certification requirements.

  • Size the valve for the flow, not just the line. The flow must hold the disc fully open at the lowest flow the plant sustains for long periods, so do not use start-up flow as the minimum. If the valve is oversized and the flow is low, the disc can flutter and wear. Give the supplier the minimum, normal and maximum flow rates on the data sheet.
  • Ask for the pressure drop at those flows, in the form of a flow coefficient (Cv or Kv) and a pressure loss figure.
  • State the closing requirement: how quickly the flow can slow and reverse, and whether non-slam performance is required, so the spring and disc can be selected for the response you need.
  • Specify the cracking pressure, which is set by the spring.
  • Confirm the installation orientation. Because a spring closes the disc, many designs can be installed in any orientation, but in vertical lines the weight of the disc acts with or against the spring depending on the flow direction, so a different spring may be needed. Confirm it for the specific valve.
  • Allow straight pipe upstream so the flow reaches the valve evenly, and keep bends and reducers clear of the outlet. The supplier states the distances for its design.
  • Name the design standard, pressure class, end connections and materials. For the valve itself, API 6D covers pipeline check valves, and MSS SP-126 covers in-line, spring-assisted, center-guided check valves, so ask which the design meets.
  • Choose the seat. Metal-to-metal seats are the usual choice and are not bubble-tight; a soft seat gives bubble-tight shutoff but is limited by temperature and chemical compatibility. State the leakage standard and test medium you require.
  • For sour service, name the materials standard: NACE MR0175 / ISO 15156 for oil and gas production, or NACE MR0103 / ISO 17945 for refining. Add any fire test (API 6FA) or fugitive-emission requirement.

Axial flow check valves from RANGER

RANGER API 6D nozzle check valves are an axial-flow nozzle design, 2" – 40", Class 150 – 2500. See API 6D nozzle check valves. For pigged lines and in-line repair, see the full-port API 6D swing check valves, and for compact installations the dual door wafer check valves. To discuss a specific duty, send the flow rates, line size and pressure class with your quote request.

Frequently asked questions

Is an axial flow check valve the same as a nozzle check valve?

Yes. Nozzle check valve describes the nozzle-shaped flow passage, and axial flow describes the disc moving along the pipe axis. RANGER lists its axial-flow design as the API 6D nozzle check valve.

Why does an axial flow check valve reduce water hammer?

A spring closes the disc as the flow slows and the disc has only a short distance to travel, so the valve is closed before significant reverse flow develops. A swing check valve closes later and slams.

Can an axial flow check valve be used in a pigged pipeline?

No. The disc and its guide stay in the flow path, so the valve is not full bore. For a pigged line, use a full-port check valve such as an API 6D swing check valve.

How much straight pipe does an axial flow check valve need?

Enough for the flow to reach the valve evenly, with bends and reducers kept clear of the outlet so the valve can open fully. The distances depend on the design, so take them from the supplier's installation guidance.

Why are axial flow check valves used on reciprocating compressors?

Reciprocating compressors produce pulsating flow. A swing check disc tends to flutter and chatter in it, while a spring-loaded axial flow disc follows the flow changes and closes quickly on each reversal.

Is there a standard for axial flow check valves?

Two commonly named ones. API 6D covers pipeline valves, including check valves, and RANGER's nozzle check valves are designed to it. MSS SP-126 covers in-line, spring-assisted, center-guided check valves. Ask the supplier which the valve meets and how it was tested.

What information does a supplier need to size one?

The line size and class, the fluid and its state, and the minimum, normal and maximum flow, pressure and temperature, plus the orientation. The minimum flow is the lowest the plant sustains for long periods, not the start-up flow.

Why does the sizing matter?

The flow has to hold the disc open against the spring. If the valve is much larger than the flow needs, the disc may not open fully and can flutter, which wears the parts. Size from the flow rates, not only the line size.

What is the pressure class and size range of RANGER nozzle check valves?

2" – 40", ASME Class 150 – 2500, designed to API 6D.